Method of calculation of air temperature in the open air layer (Metoda obliczania temperatury powietrza w otwartej warstwie powietrznej)

Piotrowski, Jerzy Z. and Olenets, Marianna and Starzomska, Mariola and Zaborek, Radosław (2012) Method of calculation of air temperature in the open air layer (Metoda obliczania temperatury powietrza w otwartej warstwie powietrznej). Structure & Environment, 4 (4). pp. 43-48. ISSN 2081-1500

[img]
Preview
Tekst
Piotrowski_Method_4_2012.pdf

Download (311kB) | Preview

Streszczenie

The building envelopes with the open air layer are common in building energy-efficient houses. In such buildings, air gap is used for moisture elimination from a surface of external wall, which improves its thermal properties. To improve the thermal quality of building envelopes with open air layer and reduce the heat transfer rate during the cold period, it is necessary to conduct more in-depth study of heat exchange in the ventilated layer of air. The article presents a mathematical model of heat transfer through building envelopes with an open air layer for the cold season. In the proposed mathematical model connective and radiant heat fluxes were considered separately.

Typ dokumentu: Artykuł
Słowa kluczowe: open air layer, thermal performance, mathematical model, convective heat flux, radiant heat flux, heat transfer