Kubicka, Katarzyna and Radoń, Urszula (2015) The assessment of fire safety of steel structural roof (Ocena trwałości pożarowej stalowego przekrycia strukturalnego). Structure & Environment, 7 (4). pp. 155-158. ISSN 2081-1500
|
Tekst
Kubicka_The-assessment_SaE_4_2015.pdf Download (419kB) | Preview |
Streszczenie
The paper provides a fire analysis of steel structural roof. The analysis was carried in accordance with the Eurocode. The fire impact on the structure was evaluated with respect to three criteria: bearing capacity, temperature and time. To carry out the numerical analysis, the Robot system was used.
Typ dokumentu: | Artykuł |
---|---|
Słowa kluczowe: | steel structures, structural roofs, fire safety, konstrukcje stalowe, przekrycia strukturalne, bezpieczeństwo pożarowe |
Tematyka: | T Technology > T Technology (General) T Technology > TH Building construction |
Dodano przez: | Agnieszka T T |
Date Deposited: | 26 Jul 2022 07:45 |
Last Modified: | 26 Jul 2022 07:50 |
URI: | http://bc.tu.kielce.pl/id/eprint/474 |
Biblioteka Cyfrowa
Podgląd |